    Description

    Altronix T2DMK7F8 kit consists of Trove2 enclosure, TDM2 DMP/Altronix backplane with one (1) 24VDC @ 10A power supply/charger, one (1) fused access power controller, one (1) voltage regulator and one (1) dual input fused power distribution module eFlow104NB Power Supply/Charger Input Voltage: 120VAC, 60Hz, 4.5A max. Main Fuse: 6.5A / 250V. Outputs Voltage: 24VDC. Current: 10A continuous. Auxiliary: Class 2 power-limited @ 1A (unswitched). Other: Overvoltage protection. Filtered and regulated. Battery Backup (not included) Type: Sealed lead acid or gel type. Fuse Rating: 10A/32VDC. Failover: Upon AC loss, instantaneous. Fire Alarm Disconnect Supervised: Latching or non-latching. EOL: 10K Resistor. Supervision AC Failure: Form “C” contacts. Battery: Form “C” contacts. Low DC Power Shutdown: Shuts down DC output terminals if battery voltage drops below 70-75% for 24V units. Prevents deep battery discharge. Indicators LED Input: 120VAC is present. DC Output: Powered. PDS8 Dual Input Power Distribution Module Input Voltage: 24VDC from eFlow104NB and 12VDC from VR6. Main Fuse: 10A / 32V. Outputs Voltage: 12VDC and/or 24VDC. Any of the eight (8) power outputs are selectable to follow power Input 1 or Input 2. Individual outputs may be set to OFF position for servicing. Output Fuses: 3A / 32V. Indicators (LED) DC Output: Eight (8) individual output LEDs. Green: 12VDC Red: 24VDC. VR6 Voltage Regulator Input Voltage: 24VDC from eFlow104NB. Output Voltage: 12VDC. Current: 6A continuous. Other: Surge suppression. Indicators LED Input: 24VDC is present. Output: Powered. ACM8 Access Power Controller Input Voltage: 24VDC from eFlow104NB. Main Fuse: 10A / 32V. Outputs Voltage: 24VDC. Eight (8) independently controlled fused outputs: a) Fail-Safe and/or Fail-Secure power outputs. Form “C” Relays rated 28VAC or VDC @ 2.5A. b) Auxiliary power outputs (unswitched). c) Any combination of the above. Output Fuses: 3.5A / 32VDC. Indicators (LED) Red LEDs: Outputs are triggered (relays energized). Green LED: FACP disconnect is triggered. Environmental Temperature Operating: 0° C to 50° C (32° F to 122° F). Storage: - 20° C to 70° C ( - 4° F to 158° F). Relative Humidity Relative Humidity 85% +/- 5%. BTU/Hr (approx.): 128 BTU/Hr.
    a.imagelink {color:#0000FF;} a:hover.imagelink {color:#0000FF;} a:visited.imagelink {color:#800080;} a.imagelink img.auctionimage { border: 2px solid #0000FF; } a:visited.imagelink img.auctionimage { border: 2px solid #800080; }
    Altronix T2DMK7F8 kit consists of Trove2 enclosure, TDM2 DMP/Altronix backplane with one (1) 24VDC @ 10A power supply/charger, one (1) fused access power controller, one (1) voltage regulator and one (1) dual input fused power distribution module
    eFlow104NB Power Supply/Charger
    Input
    Voltage: 120VAC, 60Hz, 4.5A max.
    Main Fuse: 6.5A / 250V.
    Outputs
    Voltage: 24VDC.
    Current: 10A continuous.
    Auxiliary: Class 2 power-limited @ 1A (unswitched).
    Other: Overvoltage protection. Filtered and regulated.
    Battery Backup (not included)
    Type: Sealed lead acid or gel type.
    Fuse Rating: 10A/32VDC.
    Failover: Upon AC loss, instantaneous.
    Fire Alarm Disconnect
    Supervised: Latching or non-latching.
    EOL: 10K Resistor.
    Supervision
    AC Failure: Form “C” contacts.
    Battery: Form “C” contacts.
    Low DC Power Shutdown: Shuts down DC output terminals if battery voltage drops below 70-75% for 24V units. Prevents deep battery discharge.
    Indicators LED
    Input: 120VAC is present.
    DC Output: Powered.
    PDS8 Dual Input Power Distribution Module
    Input
    Voltage: 24VDC from eFlow104NB and 12VDC from VR6.
    Main Fuse: 10A / 32V.
    Outputs
    Voltage: 12VDC and/or 24VDC.
    Any of the eight (8) power outputs are selectable to follow power Input 1 or Input 2.
    Individual outputs may be set to OFF position for servicing.
    Output Fuses: 3A / 32V.
    Indicators (LED)
    DC Output: Eight (8) individual output LEDs.
    Green: 12VDC
    Red: 24VDC.
    VR6 Voltage Regulator
    Input
    Voltage: 24VDC from eFlow104NB.
    Output
    Voltage: 12VDC.
    Current: 6A continuous.
    Other: Surge suppression.
    Indicators LED
    Input: 24VDC is present.
    Output: Powered.
    ACM8 Access Power Controller
    Input
    Voltage: 24VDC from eFlow104NB.
    Main Fuse: 10A / 32V.
    Outputs
    Voltage: 24VDC.
    Eight (8) independently controlled fused outputs:
    a) Fail-Safe and/or Fail-Secure power outputs. Form “C” Relays rated 28VAC or VDC @ 2.5A.
    b) Auxiliary power outputs (unswitched).
    c) Any combination of the above.
    Output Fuses: 3.5A / 32VDC.
    Indicators (LED)
    Red LEDs: Outputs are triggered (relays energized).
    Green LED: FACP disconnect is triggered.
    Environmental
    Temperature
    Operating: 0° C to 50° C (32° F to 122° F).
    Storage: - 20° C to 70° C ( - 4° F to 158° F).
    Relative Humidity
    Relative Humidity 85% +/- 5%.
    BTU/Hr (approx.):
    128 BTU/Hr.